Connect your robot to your lab instruments
Your robot speaks OPC UA, and your spectrometer speaks its vendor protocol. Our Gateway connects the two, so your robot can start runs, read the instrument state and receive results.
OPC UA / LADS · SiLA 2 · Gateway timestamps
// Use case · Pharma QC
Robotic NIR testing of tablets in QC
Take a QC lab that develops methods for analysing pills and tablets and wants to automate them with a robot. The robot can handle the samples: pick a pill, place it on the autosampler tray and position it under the probe.
The analytical instrument, a near-infrared (NIR) spectrometer, was controlled by hand through its vendor software. Only an operator at the screen could start a run or read a result. So an operator stepped in for every measurement: start the run, watch the screen, copy the result.
Throughput stayed at one shift and one operator. The robot could only work as fast as the person at the spectrometer screen.
// OPC UA / LADS
How your robot controls the instrument
Through the Gateway, your instrument speaks OPC UA LADS, the OPC UA companion specification for laboratory devices. Your robot already speaks OPC UA, so both sides use the same interface. The instrument-specific work sits in the connector on the Gateway, so the robot side stays standard OPC UA. LADS describes lab devices in a vendor-neutral way, so your robot can drive each instrument through the functions its connector exposes.
Read the instrument state
- Power state
- Calibration status
- Last measurement metadata
- Sample queue position
Control each measurement
- Start and stop runs
- Place and rotate the autosampler
- Trigger calibration cycles, where the instrument supports it
- Configure protocols
Receive every result
- Spectra as standardised LADS objects
- Provenance attached: serial, timestamp, protocol step
- Delivery to your LIMS or downstream pipeline, scoped with you as a custom integration
- Also deliverable as AnIML or ASM; we set up the route for your project
The robot can start the run, read the instrument state and receive the result over one interface. Each measurement can then run as a step in the robot’s protocol.
// Architecture
One data flow from robot to instrument
One architecture for every LADS-modelled instrument. You add a connector per instrument, and the Gateway stays the same.
Your vendor software keeps working in parallel. The Gateway adds a second control path for your robot.
Your NIR model in our Connector Library. Send us the model, and we confirm its status. For a new model, we build the connector: see Custom Connector Development.
// Where it fits
Robotic workcells for repetitive QC methods
// Other setups
Special cases we scope with you
// FAQ
Questions about robotic workcells
Can we keep our existing vendor software?
Yes. Your vendor software keeps running in parallel, and operators can keep using it. The Gateway adds a second control path through OPC UA LADS, so your robot can drive the same instrument as your operators.
Can you build a LADS model for our instrument?
Yes, we build the connector and its LADS model. For a well-documented device, this takes two days. We test the connector on a simulator before we connect your instrument. We scope complex devices with you. See Custom Connector Development.
Where do interlocks and safety stops live?
Safety logic stays in your robot’s controller. The Gateway is designed for laboratory use and isn’t part of any safety function or safety chain. It sits in the data and command path between robot and instrument and doesn’t act on safety interlocks: your interlocks and safety stops stay with the robot controller.
Can the robot start calibration cycles?
Where your instrument supports it, yes. The connector can expose the instrument’s calibration routine, so your robot can start it as a step in its protocol, for example at every shift change. We confirm this for your instrument when we scope the connector.
How do we buy the Gateway and connectors?
You buy the Gateway and its connectors, and they are yours. Each Gateway comes with one connector licence. Security updates come for the lifetime of the product, and optional maintenance adds new features. We scope services with you and quote for your setup.
Want your robot to drive your lab instruments?
Book a 30-minute call. Tell us your robot, your instrument and your protocol. We’ll come back with a plan for your setup.