// Food & Beverage
Food and beverage QC data, ready for your LIMS
For food, dairy, sugar, brewery and beverage labs: we connect your QC bench instruments and send their results to your LIMS, each with a Gateway timestamp. Process systems that speak OPC UA can read the same data. One architecture, from one bench to many plants.
OPC UA / LADS · SiLA 2 · Audit trail · EU CRA-ready
// Process systems
Lab results your process systems can read
CO₂, pH, fermentation gravity, temperature, flow and pressure: your SCADA logs and archives every value and raises the alarms. If your SCADA speaks OPC UA, it can also read your lab results from the Gateway, next to your production data.
// QC lab
Send lab QC results straight to your LIMS
Composition, microbial counts, colour, viscosity and sensory panels: lab measurements sign off every batch. Today, results often move from paper to spreadsheet at the end of the shift. The Gateway sends each result from your connected instruments to your LIMS, with a timestamp.
// Example setup
QC results from bench to LIMS, readable by SCADA
Gateway Touch connects your benchtop instruments, such as balances and pH meters. We confirm each model with you.
Every measurement carries a Gateway timestamp the operator can’t change.
Gateway Touch sends each result to your LIMS with its instrument context.
Process systems that speak OPC UA read the same results from the Gateway.
// Use case · Sugar production
Connect your raw-material and production QC labs
Sugar production often runs two QC labs: one tests incoming beet, the other tests samples from production. Today, much of this work happens on paper.
- Gateway Touch at busy QC stations: your team builds bench workflows for each sample type and sampling point
- Gateway 2, our standard benchtop gateway, for benches where instruments run with little operator input
- Results in your LIMS, with sampling point and process stage as agreed in your integration project
- Current QC results for production managers, in the LIMS during the shift
→ Less manual data entry in your production QC lab, and production decisions based on current QC results.
// Use case · Brewery & beverage
Compare QC and process values for each brew
Process systems that speak OPC UA can read the lab results, so your team can compare QC values and process values for each brew.
- Benchtop devices for bacterial counts and finished-product testing: send us your instrument list and we’ll confirm each model
- Gateway timestamps on every measurement, independent of the instrument clock
- Your LIMS receives each result with its instrument context, ready for the batch record
- OPC UA / LADS by default, so process systems that speak OPC UA can read the lab data. We scope brewery-management integrations with you.
Brewing combines process sensors on the tanks with lab work on the bench: CO₂, pH, density and temperature on one side, bacterial counts and finished-product tests on the other. Today, the two often sit in separate systems.
// Audit trail
A full audit trail at every connected bench
// Use case · Dairy
Traceable QC from milk intake to finished product
A dairy runs two QC streams: incoming milk control for every delivery, and product control during the production of milk, yogurt and cheese. The instrument mix is wide: real-time PCR, composition analysers, pH meters, balances and wet chemistry.
- Real-time PCR and composition results in the same dataset. We agree the connection for each analyser with you
- Benchtop instruments (pH, balances) connected through the Gateway
- One traceable record in your LIMS for each milk delivery and production batch, with a Gateway timestamp on every result from a connected instrument
- Acceptance decisions on incoming milk based on results in your LIMS, and a clear trail for root-cause analysis
→ Batch-release decisions based on QC data in one place, with a traceable record from incoming milk to finished product.
// Deployment
Start with one bench, grow to many plants
Start with one connected bench, then add instruments and benches as you grow. We quote additional connectors for your setup.
For a multi-plant group, we can pre-configure your Gateways before they ship. You manage them on your own network, through the management API.
Integration & Rollout takes around 90 days to a working platform. Your timeline depends on your scope.
Every plant runs the same Gateway family, software and standard interfaces. Each new site follows the pattern of the first one.
What you can count on
// Standards & integrations
Open standards that connect lab and plant
OPC UA / LADS
The OPC UA companion specification for laboratory devices, built on the protocol your process engineers use on the SCADA side. Every connector on our Gateway offers your instrument data over OPC UA / LADS.
SiLA 2
The lab automation standard for benches that need orchestration. We support SiLA 2 in production and publish open-source SiLA 2 Node-RED nodes.
LIMS integration
Many LIMS and production data systems offer a REST API. We connect your LIMS as a project, through its REST API or file exchange.
SCADA / OPC UA
Your SCADA can read lab results from the Gateway over OPC UA, so QC values sit next to your process values. Control and safety stay in your PLC or DCS.
FAIR data
Findable, accessible, interoperable and reusable data. We deliver your results in open formats with rich metadata, so you can trace your batches and reuse the data in your own analyses.
EU Cyber Resilience Act
EU CRA-ready: SBOM, continuous security scanning and vulnerability handling are in place. We share the SBOM under NDA.
// Recommended setup
The setup for food and beverage labs
At the bench
Gateway Touch: the Gateway with a multi-touch display. Your team builds and adjusts QC workflows at the bench. For busy QC stations.
Gateway 2: our standard benchtop gateway. It connects instruments over USB, with dongles and cables for RS-232 and Ethernet. We size your setup with you in the first call.
Data flow to your LIMS
Data Suite: lab data flows on Apache NiFi. It routes and transforms your QC results into the structure your LIMS expects.
For larger analysers, such as real-time PCR, we agree the connection with you for each project.
Our services
Integration & Rollout: we integrate your QC benches with your LIMS and SCADA and deliver the full service.
Custom Connector Development: we build a connector for your food-industry instrument and test it on a simulator first.
Training & Onboarding: we enable your team to use OPC UA / LADS, SiLA 2, AnIML and ASM in your own lab.
// FAQ
Questions from food and beverage labs
Can the Gateway run in our production QC lab?
Gateway 2 and Gateway Touch are designed for laboratory use, including QC labs that serve production. Tell us your shift pattern and we’ll plan your setup with you. Our team in Leopoldshöhe supports you during German business hours, in German or English. Support terms are agreed per contract.
How does the Gateway connect to our SCADA?
Over OPC UA, the protocol your process engineers already use on the SCADA side. OPC UA / LADS is the default interface of every connector, so process systems that speak OPC UA can read the lab data. The Gateway is designed for laboratory use and takes no part in any safety function: control and safety stay in your PLC or DCS.
Will this work with our LIMS?
We connect your LIMS as an integration project, scoped with you. The route, REST API or file exchange, is chosen in scoping. We’ve worked with several commercial LIMS and can scope an integration for yours. See LIMS integrations.
Can we start with one bench?
Yes. Start with one connected bench and add instruments as you grow; we quote additional connectors for your setup. When you add plants, the same Gateway family comes with you. We can pre-configure new Gateways before they ship, and you manage all of them on your own network. Our support works with you by phone and screen-share.
How do you support our food safety audits?
The Gateway timestamps every measurement and logs every action with its identity: who did what, and when. You export the audit trail as JSON or CSV, and a signed export lets your auditor verify the file. Ask us for supplier documentation for your audit.
How do we buy the Gateways?
You buy the Gateway and its connectors, and they are yours. Each Gateway comes with one connector licence. Security updates come for the lifetime of the product, and optional maintenance adds new features. We scope services with you and quote for your setup.
Let's plan your first connected QC bench.
A 30-minute first call. Show us your QC bench, your LIMS and your SCADA. We’ll come back with a clear plan for your setup, and a quote if you want one.
// Read more
Related pages
Product
SynConnect Gateway Touch
The Gateway with a multi-touch display. Build and adjust your QC workflows at the bench.
Service
Integration & Rollout
We integrate your QC benches with your LIMS and SCADA and deliver the full service.
Contact
Support
Our team in Leopoldshöhe supports you during German business hours, in German or English. Support terms are agreed per contract.