// Food & Beverage

Food and beverage QC data, ready for your LIMS

For food, dairy, sugar, brewery and beverage labs: we connect your QC bench instruments and send their results to your LIMS, each with a Gateway timestamp. Process systems that speak OPC UA can read the same data. One architecture, from one bench to many plants.

OPC UA / LADS · SiLA 2 · Audit trail · EU CRA-ready

Technician in hairnet and blue gloves checks a tablet beside an open stainless steel process tank

// Process systems

Lab results your process systems can read

CO₂, pH, fermentation gravity, temperature, flow and pressure: your SCADA logs and archives every value and raises the alarms. If your SCADA speaks OPC UA, it can also read your lab results from the Gateway, next to your production data.

// QC lab

Send lab QC results straight to your LIMS

Composition, microbial counts, colour, viscosity and sensory panels: lab measurements sign off every batch. Today, results often move from paper to spreadsheet at the end of the shift. The Gateway sends each result from your connected instruments to your LIMS, with a timestamp.

// Example setup

QC results from bench to LIMS, readable by SCADA

1
QC bench

Gateway Touch connects your benchtop instruments, such as balances and pH meters. We confirm each model with you.

2
Gateway timestamp

Every measurement carries a Gateway timestamp the operator can’t change.

3
Your LIMS

Gateway Touch sends each result to your LIMS with its instrument context.

4
Your SCADA

Process systems that speak OPC UA read the same results from the Gateway.

// Use case · Sugar production

Connect your raw-material and production QC labs

Sugar production often runs two QC labs: one tests incoming beet, the other tests samples from production. Today, much of this work happens on paper.

→ Less manual data entry in your production QC lab, and production decisions based on current QC results.

Stainless steel process pipework from above with three blue valve control heads showing green status lights
Rack of capped test tubes holding amber liquid samples in a quality control laboratory

// Use case · Brewery & beverage

Compare QC and process values for each brew

QC results next to your process data.
Process systems that speak OPC UA can read the lab results, so your team can compare QC values and process values for each brew.
  • Benchtop devices for bacterial counts and finished-product testing: send us your instrument list and we’ll confirm each model
  • Gateway timestamps on every measurement, independent of the instrument clock
  • Your LIMS receives each result with its instrument context, ready for the batch record
  • OPC UA / LADS by default, so process systems that speak OPC UA can read the lab data. We scope brewery-management integrations with you.

Brewing combines process sensors on the tanks with lab work on the bench: CO₂, pH, density and temperature on one side, bacterial counts and finished-product tests on the other. Today, the two often sit in separate systems.

// Audit trail

A full audit trail at every connected bench

// Use case · Dairy

Traceable QC from milk intake to finished product

A dairy runs two QC streams: incoming milk control for every delivery, and product control during the production of milk, yogurt and cheese. The instrument mix is wide: real-time PCR, composition analysers, pH meters, balances and wet chemistry.

→ Batch-release decisions based on QC data in one place, with a traceable record from incoming milk to finished product.

Gloved hand placing a PCR tube into the open sample block of a benchtop thermal cycler

// Deployment

Start with one bench, grow to many plants

01
Single plant

Start with one connected bench, then add instruments and benches as you grow. We quote additional connectors for your setup.

02
Pre-configured

For a multi-plant group, we can pre-configure your Gateways before they ship. You manage them on your own network, through the management API.

03
Rollout

Integration & Rollout takes around 90 days to a working platform. Your timeline depends on your scope.

04
Network

Every plant runs the same Gateway family, software and standard interfaces. Each new site follows the pattern of the first one.

What you can count on

80+
Instruments in our Connector Library
~90
Days to a working platform with Integration & Rollout
2 days
To build a new connector for a well-documented device
30 min
First call to scope your QC bench, your LIMS and your SCADA with you

// Standards & integrations

Open standards that connect lab and plant

OPC UA / LADS

The OPC UA companion specification for laboratory devices, built on the protocol your process engineers use on the SCADA side. Every connector on our Gateway offers your instrument data over OPC UA / LADS.

SiLA 2

The lab automation standard for benches that need orchestration. We support SiLA 2 in production and publish open-source SiLA 2 Node-RED nodes.

LIMS integration

Many LIMS and production data systems offer a REST API. We connect your LIMS as a project, through its REST API or file exchange.

SCADA / OPC UA

Your SCADA can read lab results from the Gateway over OPC UA, so QC values sit next to your process values. Control and safety stay in your PLC or DCS.

FAIR data

Findable, accessible, interoperable and reusable data. We deliver your results in open formats with rich metadata, so you can trace your batches and reuse the data in your own analyses.

EU Cyber Resilience Act

EU CRA-ready: SBOM, continuous security scanning and vulnerability handling are in place. We share the SBOM under NDA.

// Recommended setup

The setup for food and beverage labs

At the bench

Gateway Touch: the Gateway with a multi-touch display. Your team builds and adjusts QC workflows at the bench. For busy QC stations.

Gateway 2: our standard benchtop gateway. It connects instruments over USB, with dongles and cables for RS-232 and Ethernet. We size your setup with you in the first call.

Gateway Touch page →
Gateway 2 page →

Data flow to your LIMS

Data Suite: lab data flows on Apache NiFi. It routes and transforms your QC results into the structure your LIMS expects.

For larger analysers, such as real-time PCR, we agree the connection with you for each project.

Data Suite page →

Our services

Integration & Rollout: we integrate your QC benches with your LIMS and SCADA and deliver the full service.

Custom Connector Development: we build a connector for your food-industry instrument and test it on a simulator first.

Training & Onboarding: we enable your team to use OPC UA / LADS, SiLA 2, AnIML and ASM in your own lab.

Talk to us about your project →
Custom Connectors →

// FAQ

Questions from food and beverage labs

Gateway 2 and Gateway Touch are designed for laboratory use, including QC labs that serve production. Tell us your shift pattern and we’ll plan your setup with you. Our team in Leopoldshöhe supports you during German business hours, in German or English. Support terms are agreed per contract.

Over OPC UA, the protocol your process engineers already use on the SCADA side. OPC UA / LADS is the default interface of every connector, so process systems that speak OPC UA can read the lab data. The Gateway is designed for laboratory use and takes no part in any safety function: control and safety stay in your PLC or DCS.

We connect your LIMS as an integration project, scoped with you. The route, REST API or file exchange, is chosen in scoping. We’ve worked with several commercial LIMS and can scope an integration for yours. See LIMS integrations.

Yes. Start with one connected bench and add instruments as you grow; we quote additional connectors for your setup. When you add plants, the same Gateway family comes with you. We can pre-configure new Gateways before they ship, and you manage all of them on your own network. Our support works with you by phone and screen-share.

The Gateway timestamps every measurement and logs every action with its identity: who did what, and when. You export the audit trail as JSON or CSV, and a signed export lets your auditor verify the file. Ask us for supplier documentation for your audit.

You buy the Gateway and its connectors, and they are yours. Each Gateway comes with one connector licence. Security updates come for the lifetime of the product, and optional maintenance adds new features. We scope services with you and quote for your setup.

Let's plan your first connected QC bench.

A 30-minute first call. Show us your QC bench, your LIMS and your SCADA. We’ll come back with a clear plan for your setup, and a quote if you want one.

    Scientist in a lab coat explains something with open hand gestures to a listening colleague in a laboratory

    // Read more

    Related pages

    Product

    SynConnect Gateway Touch

    The Gateway with a multi-touch display. Build and adjust your QC workflows at the bench.

    Service

    Integration & Rollout

    We integrate your QC benches with your LIMS and SCADA and deliver the full service.

    Contact

    Support

    Our team in Leopoldshöhe supports you during German business hours, in German or English. Support terms are agreed per contract.