// Chemical industry
Your analytical methods in one LIMS dataset
For petrochemical, adhesives and coatings labs, we connect your benchtop devices and analytical instruments and bring their data into one LIMS dataset. Your robots and automation scripts read each connected instrument over OPC UA / LADS or SiLA 2, and drive it where the instrument allows. Every result the Gateway captures carries a Gateway timestamp. We scope your LIMS integration as a project.
OPC UA / LADS · SiLA 2 · AnIML · Allotrope ASM · EU CRA-ready
80+
and every connector speaks OPC UA / LADS
2 days
for a well-documented device; we test it on a simulator first
90
typical for Integration & Rollout
30 min
where we scope your instruments and your LIMS with you
// Today
Results still reach your LIMS by hand.
Adhesives, coatings and petrochemical labs run experiments that take many hours or several days: temperature ramps, dwell phases, rheology cycles and ageing studies. Today, a technician sets each setpoint by hand, watches the screen and writes down each value. Often, a technician can run only one such experiment a day.
Your analytical methods sit in separate vendor software: DSC, TGA, mechanical testing, spectroscopy, chromatography and particle size. Each one has its own file format. Results are typed into the LIMS by hand, days after the measurement.
// Connected
How the Gateway brings results to your LIMS
The Gateway connects your rheometer, viscometer and other benchtop devices, and offers their data over OPC UA / LADS. Your automation scripts read each instrument while it runs. Where the instrument allows remote control, they also drive it.
Every result carries a Gateway timestamp and its instrument context. The Gateway buffers each result until your LIMS has received it. Data Suite routes the data into the fields your LIMS expects. We size your setup with you in the first call.
// Use case · Automation
Let your scripts and robots drive the bench
The Gateway captures each reading from your connected devices, so your technicians spend less time writing values down and more on analysis and decisions.
- OPC UA / LADS on every connector: your scripts and robots read each instrument as it measures
- SiLA 2 in production: your orchestration software drives instruments that support remote control
- Gateway timestamps on every measurement, independent of the instrument clock
- Results buffered on the Gateway until your LIMS has received them, for as long as you configure per connector
// Use case · Many methods
Compare mechanical, thermal and spectroscopy results
A petrochemical or coatings R&D lab runs many methods on the same material: Charpy / Izod, tensile, DSC, TGA, infrared, XRF, chromatography, particle size and DMA. Each method has its own vendor software and file format. Today, someone collects a dozen exports by hand to compare them.
- The Gateway reads your benchtop devices (rheometers, viscometers, balances, pH meters) as they measure
- Your larger instruments (DSC, chromatography, XRF, mechanical testers): we agree the capture route for each one
- Data Suite routes and transforms the data into the structure your LIMS expects
- One LIMS dataset for your connected methods, with a timestamp and instrument context on each result
→ Less manual data entry, and cross-method analysis your team runs as a simple query.
// R&D and QC
Connected instruments for chemicals R&D and QC
// Use case · Coatings
Coatings tests: colour, gloss, viscosity and surface
Coatings R&D and QC use many physical methods. They measure colour on translucent and reflective samples, surfaces on textiles and solids, texture and gloss. They test viscosity for formulations and incoming raw materials, plus adhesion, abrasion and hardness on coated samples. Each method has its own benchtop and vendor app.
- Connectors for colour, gloss, viscosity, surface and material-testing instruments. We confirm the status for your models.
- Bench workflows on Gateway Touch: build and adjust them on its display
- LIMS push from Gateway Touch, with a Gateway timestamp and instrument context on each connected measurement
- One dataset for your benchtop devices and, once we agree the capture route, your larger instruments, with Data Suite routing the data
→ Faster formulation cycles, and clear traceability for each result you state (“this coating passed N abrasion cycles”).
// How you start
Start with one bench, grow to many sites
Place the Gateway on your bench and add your devices in the management UI. A single R&D lab starts this way, with plug-and-play setup.
For a group rollout, we can pre-configure your gateways before they ship to your sites. You manage them on your own network, through the management API. In production, you use certificates from your own CA.
Each site runs the same setup on its own network. Integration & Rollout takes around 90 days to a working platform.
A large site and a small lab use the same hardware and the same software. Your team works with one operations runbook as you grow.
Facts for planning your project
// Standards & integrations
How open standards connect your methods
OPC UA / LADS
The OPC UA companion specification for laboratory devices. Every connector models your instrument as OPC UA nodes. Robots and scripts read them, and drive them where the instrument allows.
SiLA 2
The lab automation standard for instrument control, feature by feature, over gRPC. We support SiLA 2 in production, so your orchestration software reaches the bench.
AnIML
An open XML format for analytical data. Spectra, chromatograms and mechanical-test results can be delivered as AnIML. We set up the route for your project.
Allotrope Simple Model (ASM)
The open semantic model from the Allotrope Foundation, built for analytical data. Data can be delivered as ASM, and we set up the route for your project.
LIMS and ELN integration
Most modern LIMS and ELN systems offer REST APIs. We connect your LIMS or ELN through its API, as an integration project. See how we approach specific systems.
EU Cyber Resilience Act
EU CRA-ready: a hardened OS, a CycloneDX SBOM and a vulnerability disclosure pipeline are in place today. We share our SBOM under NDA for your review.
// Recommended setup
The setup for chemicals R&D and QC labs
Gateways for your bench
Gateway Touch: bench gateway with a touch display, where you build bench workflows. For R&D and QC operators.
Gateway 2: our standard benchtop gateway, managed over your network. For long-cycle experiments and benches run by your automation scripts.
Data flow to your LIMS
Data Suite: data flows built on Apache NiFi. It routes and transforms the data from your gateways into one LIMS dataset, in your cloud account or on your own servers.
Services for your project
Custom Connector Development: a connector for your specialised instrument, in two days for a well-documented device
Integration & Rollout: we integrate your setup and deliver the full service
Training & Onboarding: we enable your team to use OPC UA / LADS, SiLA 2, AnIML and ASM in your own lab
// FAQ
Questions from chemicals labs
Can our automation scripts drive the instruments?
Yes, where the instrument supports remote control. Every connector offers your instrument over OPC UA / LADS, and we support SiLA 2. Your scripts and robots read the data as it is measured and send the next command.
The Gateway is designed for laboratory use and sits outside your safety chain: safety functions, such as over-temperature cut-outs and interlocks, stay with your instruments and your site safety systems. Ask us how a run handles faults in your setup.
How do DSC, chromatography or XRF results reach our LIMS?
We agree the capture route for each of these instruments with you. Data Suite then routes and transforms the results into structured fields in your LIMS. Send us your instrument list, and we confirm the route for each model.
Can we start on a single bench with a small team?
Yes. Place the Gateway on the bench, add your benchtop devices in the management UI, and start measuring. When you add sites later, the model stays the same. You manage every gateway on your own network, through the management API. We can pre-configure new gateways before they ship.
Where does the Gateway go in an ATEX lab?
The Gateway is designed for laboratory use and for installation in the safe area only, outside the explosive-atmosphere zone; it carries no ATEX rating. Connections to instruments inside a zone are planned with your site safety team, and we advise on the layout for your site.
Does it work with our LIMS or ELN?
Most modern LIMS and ELN systems offer REST APIs, and we integrate there. Each LIMS or ELN integration is a project we scope with you. We’ve worked with several commercial systems. See how we approach specific systems on LIMS integrations, or talk to us about yours.
How do you support REACH data preparation?
We deliver your measurement data in structured form, with a Gateway timestamp and instrument context on every result the Gateway captures. That gives the team compiling your IUCLID dossier clean input. OPC UA / LADS is the default interface, and data can also be delivered as AnIML or ASM. We set up the route for your project.
Let's plan your first connected bench.
Book a 30-minute call. Show us your methods, your instruments and your LIMS. We’ll come back with a clear plan, a scoped proposal and a quote if you want one.
// Going deeper
Related pages
Product
Data Suite
Data flows built on Apache NiFi. Data Suite routes your gateway data into one LIMS dataset.
Service
Custom Connector Development
A connector for your specialised instrument. Two days for a well-documented device, tested on a simulator first. We quote complex devices for your setup.
Standard
Allotrope Simple Model (ASM)
An open semantic model for analytical data. We deliver ASM where your pipeline needs it.