// Connectors · Instrument category

Turbidimeters.

We connect your turbidimeters and capture every reading with its method: NTU, FNU or FAU. Each result carries a Gateway timestamp, ready for your audit trail and for the report a regulator reads next year.

Benchtop and in-line turbidimeters · NTU, FNU and FAU method context · Every result timestamped at the source

Benchtop laboratory turbidimeter next to a filled sample cuvette on a white lab bench

// Instrument types

Turbidimeter types and the labs that use them

  • Lab turbidimeters: benchtop measurement of batch or discrete samples
  • In-line process turbidimeters: food and beverage production, breweries, dairy processing
  • Benchtop nephelometers: a closely related category with a different detection geometry

Labs that rely on turbidity data:

  • Environmental labs: drinking water, surface water and wastewater testing
  • Water authorities: compliance monitoring and regulatory submissions
  • Brewery QA: clarity control and release before packaging
  • Dairy processing: use cases we plan with you
  • Pharma and biotech: formulation clarity and solution preparation QC

SynConnect is designed for laboratory use and sits outside your safety functions. Control and safety stay in your PLC or DCS. Process systems that speak OPC UA can read the turbidity data.

// Interfaces

Interfaces on today's turbidimeters

  • RS-232 with vendor-specific commands: most benchtop and older in-line units
  • USB: newer benchtop and portable units
  • Analogue outputs: common on installed in-line sensors
  • OPC UA: newer industrial in-line systems

Gateway 2 connects your turbidimeters over USB, with the right dongle or cable for RS-232, point-to-point Ethernet or analogue sensors. Tell us your model, and we’ll confirm its status: Available, In testing or On request.

// Turbidity records

Three things every turbidity record needs

1 · One timeline across multi-day campaigns. Turbidimeters drift over time: light source intensity changes, optical surfaces collect contamination and calibration baselines shift. To audit a long campaign, you need every reading on one timeline. The Gateway timestamps each reading, independent of the instrument clock.

2 · The method behind each value. Different methods give different numbers for the same sample. NTU uses white light at 90° (EPA 180.1). FNU uses infrared light at 90° (ISO 7027). FAU measures how much infrared light passes through the sample (ISO 7027). Your protocol defines the method. We record the method designation with every value.

3 · Records for regulators and release. Your turbidity data ends up in regulatory submissions, release records or batch records. Each record needs to show when, by whom, with which calibration state and which method. We capture this context wherever the instrument or your bench workflow provides it.

// Separate records

Today

Turbidity value: 2.4 FNU. The method is noted in the operator’s logbook. The calibration state sits in a separate spreadsheet. The timestamp comes from the instrument’s own clock. Your auditor rebuilds each result from three sources, and one of them is paper.

// One record

Connected

Turbidity value: 2.4 FNU (ISO 7027). Each reading carries its method designation, a Gateway timestamp and the instrument identity. Calibration state and operator identity are added where the instrument or your bench workflow provides them. Your auditor queries one system and sees each reading with the context recorded for it.

// What you get

What you get with connected turbidimeters

1

A Gateway timestamp on every reading

Every reading carries a timestamp from the Gateway, independent of the instrument’s clock. Readings from long campaigns line up on one timeline. You can trace drift against calibration events where the instrument reports them.

2

Method context with every value

Every value carries its method designation (NTU, FNU or FAU) and the instrument configuration. Where the instrument reports its calibration state, we add that too.

3

Results delivered to your LIMS or ELN

We deliver your measurements into your LIMS, ELN or batch records, the sources your regulatory reporting draws on. No manual transcription in between. We scope each LIMS or ELN integration with you.

4

Calibration context with your readings

Where the instrument reports calibration over its interface, calibration events can sit next to the readings that follow, so drift shows as a trend in your data. Ask us how we’d set up calibration records for your instruments.

We connect your turbidimeters and deliver their data, timestamped and in context, to your LIMS, ELN or cloud.

Facts for planning your project

3
Methods recorded: NTU, FNU and FAU, each kept with its reading
80+
Instruments in our Connector Library
OPC UA
Default output of every connector, so process systems that speak OPC UA can read the data
2 days
New connector for a well-documented device. We build and test on a simulator first and scope complex devices with you.

Want your turbidimeters connected to your LIMS or ELN?

Tell us your turbidimeter models and methods, such as US EPA Method 180.1 or ISO 7027. Name the rules your data must meet, for example the EU Drinking Water Directive, and the systems it should reach. We come back with the connector mapping and a scoped proposal.

    Scientist in a lab coat explains something with open hand gestures to a listening colleague in a laboratory

    // Related pages

    Standards, security and food labs in detail

    Why Synefex

    Open standards

    Open standards on every connector, so your data stays readable in any tool that speaks them.

    Products

    Security architecture

    How the Gateway protects your data and keeps a complete audit trail.

    Solutions

    Food & Beverage

    Connected QC for brewery and beverage labs, including clarity checks.