Electrochemistry & Liquid Analysis.
Connect your pH, conductivity, ORP, DO and ISE meters to your LIMS and ELN. These probes drift over time, and their accuracy depends on calibration. With a SynConnect Gateway, every reading arrives with its Gateway timestamp and, where the meter reports it, its calibration state.
pH, conductivity, ORP, DO and ISE data, captured over RS-232 or USB, ready for your LIMS and ELN and readable over OPC UA.
// Instrument family
Electrochemistry probes and meters
- pH meters: for example Mettler Toledo (SevenEasy, SevenCompact, SevenExcellent, over MT-SICS), Hach, Hanna, WTW
- Conductivity meters
- ORP / redox probes
- DO (dissolved oxygen) probes
- ISE (ion-selective electrode) systems
- Multiparameter handhelds (for example Xylem’s WTW and YSI lines): several measurements from one device
- In-process probes (for example Hamilton, Endress+Hauser), which usually run on SCADA or DCS systems
The manufacturers and models named are examples from this instrument family. Tell us your model, and we’ll confirm its status: Available, In testing or On request.
// Connectivity
Probe interfaces: RS-232, USB and OPC UA
Most benchtop meters send their data over RS-232. Newer in-process systems often speak OPC UA.
- Vendor-specific RS-232: benchtop meters (for example Mettler Toledo, Hach, Hanna, WTW). The data output differs by vendor and model.
- OPC UA: newer in-process systems
- USB: portable and handheld multiparameter units
Where we connect a meter, our connector translates its serial or USB output into OPC UA / LADS, the default interface on every connector. Your systems see one consistent interface.
// What we solve
Five probe-data tasks and how we support them
1 · Calibration tracking. pH and conductivity probes drift, and DO membranes age. Auditors ask when each probe was last calibrated, by whom, and with which slope and offset. Where your meter reports its calibration data, the connector passes it on with the readings, and we set up the calibration records with you.
2 · Readings straight to your LIMS. Today, someone reads the value and types it into the LIMS. A connected meter sends each reading to your LIMS directly, the same way as a connected balance.
3 · Probe-to-sample linkage. Many labs run several probes at once, and water-quality labs may run 8+. Where the meter reports the probe ID, each reading carries it, so a flagged result links straight to its probe.
4 · Bench and process in one lab. Benchtop grab samples and in-process probes differ in data, timing and target system. Many labs run both. Bench readings reach your LIMS or ELN, and process systems that speak OPC UA can read the same data.
5 · Calibration state at the moment of each reading. Was the probe in calibration when it took this specific reading? Where the meter reports its calibration state, the connector attaches it to the reading, so the answer is part of the record.
// Benchtop
Send bench readings to your LIMS
Lab QC, water testing and biotech bench work take one reading per sample. We remove the transcription step. Each reading gets its provenance and, where available, the calibration state at the moment of the reading.
Your target system is usually a LIMS or ELN. With a Gateway, each reading reaches it with its Gateway timestamp, one sample at a time.
// In-process
In-process probes: continuous data streams
Bioreactor pH, in-line conductivity in breweries and water-treatment monitoring produce continuous data, with a new value every few seconds.
SynConnect is designed for laboratory use. Process systems that speak OPC UA can read the data from your Gateway. Control and safety stay in your PLC or DCS.
// What you get
What you get with connected probes and meters
Calibration events, captured
When your meter reports a calibration, the connector captures the details it sends, such as time, operator, slope and offset. Ask us how we set up calibration records for your probes.
Provenance on every reading
Every reading through a SynConnect Gateway carries a Gateway timestamp. Probe ID, calibration state and operator ID are added wherever the meter, sensor or Gateway login provides them. “Was this probe in calibration?” becomes a query on your data.
One data set for many probes
In a lab with many probes, such as a water-quality lab with 8+ probes, readings from every connected probe arrive in one consistent data set, each tied to its probe ID where the meter reports it.
OPC UA for process systems
SynConnect is designed for laboratory use. Process systems that speak OPC UA can read the data, with the same Gateway timestamps as your bench data. Control and safety stay in your PLC or DCS.
// Bench and process
Bench and process readings share one data structure.
If your lab runs benchtop grab samples and in-process probes, you get one uniform data layer. The instruments differ, but your systems receive the same data structure. Method context, calibration state and probe ID appear the same way wherever the meter reports them.
On the bench, a Gateway 2 connects meters over USB, with dongles and cables for RS-232. A SmartCable (coming Q1 2027) connects one meter and uses a Gateway or PC as its host. We size your setup with you in the first call.
Electrochemistry integrations at a glance
Want your pH, conductivity or DO meters connected to your LIMS?
Tell us your probe models, where you use them (bench, process or both) and your target systems. We come back with the connector plan, how calibration data from your meters can be carried, and a scoped proposal.
// Going deeper
Related pages
Why Synefex
AI access through the MCP Server
Ask your lab data questions in plain language. Example prompts: “show me the pH trend on bioreactor 2” and “is probe 3 still in calibration?”
Product
Secure lab data by design
See how the Gateway protects your data: signed connectors, TPM-protected keys and a full audit trail.
Why Synefex
Open standards on every connector
How our connectors turn serial and USB meter data into OPC UA / LADS.