// Balance connectors

Balances & gravimetric processes.

Many balance readings still end up in a paper notebook, on a thermal printer or in a desktop application. We connect your balances to your LIMS, ELN and cloud. Every reading the Gateway receives carries a Gateway timestamp, independent of the balance clock, ready for your audit trail.

Balance data over MT-SICS, SBI and RS-232, timestamped at the Gateway.

Analytical balance with glass draft shield weighing white powder on paper, display reading 0.1504 g

// Balance types

Balance types and lab applications

Precision, analytical, micro, industrial or dosing balance: tell us your models, and we’ll confirm the connection status for each.

Typical lab applications:

  • Pharma weighing: component dispensing, formulation and QC checks
  • Chemical formulation and dosing
  • Food and beverage QC
  • Environmental sample preparation
  • Academic and research weighing
  • Automated dispensing systems
  • Robotic weighing within larger pipetting and sample-prep workflows

// Your lab today

How balances record data today

In a typical lab, balances record their readings in one of three ways:

Readings written down by hand

The operator tares the balance, places the sample, waits for a stable weight and writes the number down. Someone then types it into the LIMS or ELN. Many labs with low sample volumes work this way.

Thermal printer for regulated records

The balance sends stable weight, date, time and metadata over RS-232 to a thermal paper-roll printer. The paper gives you a record for the audit. To reach your LIMS, the values are still typed in or scanned.

Vendor software on a desktop PC

Mettler Toledo or Sartorius companion software runs on a PC, connected over USB or RS-232 with vendor-specific protocols. Your LIMS then reads from one more application.

For each of these setups, we scope how your balance connects to your systems. Connected balances deliver their readings to your LIMS, ELN or cloud.

// Protocols

Balance protocols: from MT-SICS to RS-232

  • MT-SICS (Mettler Toledo Standard Interface Command Set): the Mettler Toledo serial command interface.
  • SBI (Sartorius Balance Interface): the Sartorius standard, spoken by all Sartorius balances over USB, RS-232 or Ethernet.
  • Generic RS-232: older balances and many third-party instruments.
  • KCP (KERN Communication Protocol): the KERN standardised command set, broadly MT-SICS-compatible, over RS-232 or RS-485.
  • Ohaus RS-232: the Ohaus ASCII command set across the Scout, Navigator, Explorer and Discovery series.

We translate the vendor protocol into OPC UA / LADS, so your systems read your connected balances the same way. These protocols and vendors are examples from this instrument family. Tell us your model and we’ll confirm its status: Available, In testing or On request.

On the bench: Gateway 2 connects the balance over USB, with dongles and cables for RS-232 and Ethernet point-to-point. We size your setup with you in the first call.

// Weighing tasks

Seven weighing tasks in a connected lab

1 · Timestamp integrity. On many balances, operators can change the local clock. The Gateway stamps every reading with its own timestamp, so your record stays independent of the balance clock. Read how Gateway timestamps work on the Gateway 2 page.

2 · Manual transcription. Values read from the screen and typed into the LIMS or ELN cost time and invite errors, often across shift changes. Once your LIMS or ELN integration is in place, connected balances deliver each value with its timestamp, ready for your records.

3 · Drift and calibration tracking. Auditors ask when a balance was last calibrated and whether it was in spec at the time of a measurement. Ask us how we’d set up calibration records next to your weighing data.

4 · Many balances on one site. A site with 20+ balances needs to know the state and use of each balance. Each Gateway makes its audit trail and operational data available through the management API, for your monitoring tools.

5 · Dosing and dispensing. Dosing workflows need the stable balance reading. The Gateway delivers each reading over OPC UA / LADS for your dosing or automation software to read. Control stays in your dosing system.

6 · Four-eyes principle. In regulated environments, many weighing steps need a second operator as a witness. The Gateway record gives the witness an independent, timestamped reading to check against. Your QA decides how to use it.

7 · Robotic and autonomous weighing. Robots weigh components, powders and liquids and run whole protocols together with pipetting robots. Over OPC UA / LADS, your robots and automation scripts read the balance and, where it supports it, control it.

// What you get

What you get with connected balances

1

Gateway timestamps

Every weighing carries a timestamp from the Gateway. A change to the balance clock leaves the Gateway record unchanged. You get an independent timeline for your audit trail.

2

Every reading, captured

Where the balance supports polled or continuous output, the Gateway captures every reading, including values nobody saved or printed. Your downstream systems receive a continuous data stream.

3

Weighing inside automated workflows

Make weighing one step of a larger workflow: robotic dispensing, sample prep or automated dosing. Your robots and automation scripts read the balance over OPC UA / LADS, next to your other connected instruments.

4

Monitoring for many balances

Each Gateway keeps its audit trail and operational data on your network. Your monitoring tools pull them through the management API, across every Gateway on your site.

// Calibration

Calibration records for your balances

Calibration data belongs next to every weighing in your audit trail. Some balances supply a digital calibration certificate (DCC) as machine-readable XML, often with a PDF version. Tell us which of your balances supply a DCC, and we’ll check the capture route for your models.

// Pharma QC

Use case: Gateway timestamps in pharma QC

In a pharma QC lab, balance dates could be changed locally at the instrument, and the printed records followed the balance clock. The lab now routes its balance readouts through our Gateways. Every measurement carries a Gateway timestamp, independent of the balance clock. The Gateway 2 page shows how the timestamps and the audit trail work.

→ Gateway timestamps are part of every connected balance from day one. Your audit trail starts with the first weighing.

Gloved hands dosing powder with a spatula onto the pan of an analytical balance with a draft shield
Collaborative robot arm lowering a capped vial into an analytical balance, a vial rack and a second balance behind

// Robotics and fleets

Balance data for robots and fleet planning

Two topics belong together here: robotic sample processing and device utilisation. Robots weigh components, powders and liquids and run combined weighing and pipetting protocols. High-value balances that are rarely used tie up capital, so you want to know how often each one is used.

→ Your balances become part of your automated protocols, and your fleet decisions rest on your own weighing data.

We connect your instruments and deliver their data, timestamped and in context, to your LIMS, ELN or cloud.

Balance integrations at a glance

2 days
Custom connector for a well-documented device, simulator first
OPC UA
Open standard on every connector: OPC UA / LADS by default
30 min
First call to map your first balance integration with you
80+
Instruments in our Connector Library, with new connectors added regularly

Want your balances connected to your LIMS or ELN?

Tell us your balance models, the workflows you want to connect (weighing, dosing, robotic protocols) and your regulatory environment. We come back with the connector mapping, the audit-trail setup and a scoped proposal. A 30-minute first call is enough to map your first integration.

    Scientist in a lab coat explains something with open hand gestures to a listening colleague in a laboratory

    // Going deeper

    Related pages

    Product

    Gateway 2

    How Gateway timestamps and the audit trail protect your balance records.

    Why Synefex

    AI-readiness via MCP

    Example prompt: “Read balance 4 and plot today’s weighings.” We confirm the actions for your instruments during setup.

    Product

    Connector Library

    Our Connector Library covers 80+ instruments. Send us your model, and we’ll confirm its status.