OPC UA + LADS.
Every connector we build speaks OPC UA / LADS by default, so your systems read every connected instrument the same way. OPC UA is the foundation. LADS is the companion specification for lab devices, built on top.
OPC Foundation member · Part of the LADS core community · OPC UA / LADS by default
Background photo: TFS.19, CC BY-SA 4.0, via Wikimedia Commons (cropped, retouched)
// OPC UA
OPC UA: secure data exchange between machines
OPC UA (Open Platform Communications Unified Architecture) is the open standard for secure data exchange between machines and software. The OPC Foundation publishes it, and it is also the international standard IEC 62541.
OPC UA runs on any platform, from a small embedded device to a server in your data centre. Three ideas make it useful in the lab:
- Information modelling: every value can carry its type, unit and meaning, in a structure a client can browse
- Client-server access: a client reads values on demand, subscribes to changes or calls methods on the device
- Security in the protocol: certificates, signing, encryption and audit events, explained further down this page
Companion specifications build on this base. Each one describes a type of equipment in a shared model. LADS is the companion specification for laboratory devices.
What we deliver: every connector we build runs an OPC UA server on the Gateway. Your OPC UA-capable systems read every connected instrument through one standard interface.
// What LADS adds
LADS, the OPC UA standard for lab devices
LADS (Laboratory and Analytical Device Standard) is the OPC UA companion specification for laboratory and analytical devices, published as OPC 30500-1 (Part 1: Basics). A joint working group of the OPC Foundation and industry associations developed it. Version 1.0 was published in November 2023.
LADS describes every lab device with the same building blocks, whatever the device type. A balance, a centrifuge and a spectrometer all appear as a device with functional units, functions, programs and results.
LADS builds on three OPC UA specifications: Devices (OPC 10000-100), Asset Management Basics (OPC 10000-110) and Machinery (OPC 40001-1). Identification and asset data follow the same rules as for other OPC UA machines.
The specification covers these use cases:
- Remote monitoring of measured values, alarms and events
- Function-based remote control, for example changing a setpoint or opening a lid
- Program-based remote control: a LIMS or scheduler starts a method and follows its progress
- Results management, including intermediate results and their metadata
- Device and fleet management, condition monitoring and maintenance
What we deliver: our connectors structure your instrument data to the LADS model, so your systems read devices from different vendors in the same shape.
// Information model
How a LADS device is structured
LADS shows a device in two views. The hardware view lists its physical components, nameplates and maintenance tasks. The functional view shows what the device does.
The functional view is where your systems work: functional units hold functions and a program manager, and the program manager holds templates, the active program and results.
Functional units
A functional unit is a virtual device inside the instrument. An instrument with two independent chambers can have two. Each unit has its own state and usually serves one client at a time.
Functions
Sensor functions report measured values with units and ranges. Control functions hold a setpoint, such as a temperature or a speed. Cover and timer functions handle lids and run times.
Programs and results
The program manager stores methods as program templates. A client starts a program, follows the active step and collects the results, linked to the samples and the job ID.
What we deliver: each connector maps your instrument to this structure. We model the functional units, functions and results it offers and confirm the model with you.
// State machines
Every state is visible to your systems
LADS uses state machines to show what a device is doing. Every OPC UA client sees the same states and can react when they change.
- Device state: initialisation, operate, sleep or shutdown, plus an operation mode such as setup, processing or maintenance
- Functional unit state: stopped, running, stopping, aborting, aborted and clearing. Methods such as Start, Stop and Abort change the state.
- Running sub-states: hold, suspend and complete, based on the PackML state model (ISA-TR88.00.02)
- Functions with their own states: control functions and covers, for example to open, close or lock a lid
- One summary status: the machinery item state sums up the whole device, like a stack light
What we deliver: our connectors expose the states your instrument reports. Your scheduler or SCADA sees whether the instrument is ready, running or needs attention. Where the instrument supports it, your systems start and stop it through the same methods.
// Our connectors
Our connectors: one LADS server per instrument
Each connector runs an OPC UA server with the LADS information model on the Gateway. The LADS server comes as standard on Gateway 2 and Gateway Touch.
- Connectivity module: speaks your instrument’s own protocol, for example MT-SICS on Mettler Toledo balances and pH meters, or SBI on Sartorius balances over USB, RS-232 or Ethernet
- Target model: structures your data to the LADS model and labels it with Allotrope Foundation Ontologies (AFO) terms, so it maps cleanly to ASM
- LADS server: publishes the device, its functional units and functions, plus programs and results where your instrument has them, as OPC UA nodes your systems browse, read and subscribe to
- Gateway timestamps: every measurement carries a Gateway timestamp, independent of the instrument’s clock
If your system works with REST, an optional connector service delivers the same data over REST. A Node-RED flow can also pass it on.
Our Connector Library covers 80+ instruments. For a new, well-documented device, we build the connector in two days. We scope complex devices with you.
To see the Gateway that runs your connectors, visit the Gateway 2 page.
// Security
OPC UA security for your lab network
OPC UA has security built into the protocol. It covers who may connect, how the data travels and what happened.
- Application authentication: client and server prove their identity with X.509 certificates before they exchange data
- Signing and encryption: in Sign mode every message is signed against tampering. Sign & Encrypt also encrypts the content.
- User authentication: a session can carry a user identity, for example a user name and password or a user certificate. Access rights can follow the user’s role.
- Audit events: the specification defines audit events for security-relevant actions, such as opening a session or writing a value
What we deliver: our connectors use the Basic256Sha256 and Aes256_Sha256_RsaPss security policies in Sign and Sign & Encrypt modes. Gateways ship with self-signed certificates, ready for your own CA-issued certificates in production. The Gateway keeps an audit trail with the identity behind each action, and you export it as JSON or CSV.
// Your systems
Read your instruments from LIMS, ELN and SCADA
Any OPC UA client connects to the LADS server, browses the model and finds each value by its type. Your systems use it in four ways.
LIMS and ELN
An OPC UA-capable LIMS or ELN reads results and their metadata directly from the LADS server. We connect other systems as an integration project.
SCADA and monitoring
SCADA systems and plant historians subscribe to live values, alarms and device states. Your lab data sits next to your process data. Control and safety stay in your PLC or DCS.
Data Suite
Data Suite, our data-orchestration tool built on Apache NiFi, takes the data from the Gateway. It routes it to your LIMS, ELN, SCADA, notification systems or FHIR targets.
Scripts, schedulers and Node-RED
Your own scripts and schedulers use any OPC UA library. Our open-source LADS nodes for Node-RED bring the same data into your flows.
What we deliver: we set up the route to each of your target systems, from a direct OPC UA connection to a Data Suite flow.
// Who benefits
What OPC UA / LADS gives each team
IT and OT teams
One protocol, one data model. Certificates and encrypted connections follow the OPC UA standard your OT team knows. The Gateway works entirely inside your network.
Lab teams
Results in context. Your results reach your LIMS or ELN with their units and a Gateway timestamp, ready to use. An instrument from another vendor arrives in the same shape.
Instrument manufacturers
A standard interface for your devices. Your customers’ systems read your instruments over OPC UA / LADS. Ship them with our Gateway, or integrate our technology into your device. See our OEM programme.
// OPC Foundation
Member of the OPC Foundation
The OPC Foundation publishes OPC UA and its companion specifications, including LADS.
As a member, we build our connectors to these specifications, so your OPC UA client reads their data directly.
// LADS core community
Part of the LADS core community
Through the LADS core community, we follow the specification as it develops.
Our contribution: open-source LADS and SiLA 2 nodes for Node-RED, on GitHub, npm and the Node-RED library, with working examples.
Ask us about our LADS Validator.
// FAQ
Questions about OPC UA and LADS
What is the difference between OPC UA and LADS?
OPC UA defines how data travels and how it is secured. LADS defines what a lab device looks like in OPC UA: device, functional units, functions, programs and results.
Which instruments can you expose as a LADS server?
Our Connector Library covers 80+ instruments. Send us your instrument list, and we confirm the status of each model. For a new, well-documented device, we build the connector in two days.
Can our systems control the instrument as well as read it?
LADS covers both. Where your instrument supports it, your systems start programs, change setpoints or stop a run through standard OPC UA methods. We confirm the functions for your model.
Does our LIMS need to speak OPC UA?
An OPC UA-capable LIMS or ELN reads the LADS server directly. Other systems receive the data through Data Suite or an optional REST service. We set up the route with you.
How is the connection secured?
Our connectors use the Basic256Sha256 and Aes256_Sha256_RsaPss policies in Sign and Sign & Encrypt modes. You replace the delivered self-signed certificates with certificates from your own CA.
What are AFO semantics, and why do they matter?
AFO are the Allotrope Foundation Ontologies, a shared vocabulary for lab data. Our connectors label your data with AFO terms, so it maps cleanly to the Allotrope Simple Model (ASM).
How do we look inside a LADS model?
Any generic OPC UA client browses the model and shows each node with its type. In a follow-up walkthrough, we show you the LADS model of your instrument on a Gateway.
Learn it with us: we train your team to work with OPC UA / LADS, SiLA 2, AnIML and ASM in your own lab. Training & Onboarding →
// External references
The specifications and tools we build on:
- OPC Foundation: opcfoundation.org
- LADS information model: OPC 30500-1 (Part 1: Basics), the companion specification published by the OPC Foundation, online at reference.opcfoundation.org
- OPC UA: also published as the international standard IEC 62541
- open62541: open62541.org, the OPC UA library stack we build on
Want to see your instrument in OPC UA / LADS?
Book a 30-minute first call and tell us which instrument you use. If its connector is in our Connector Library, we show you its LADS object model on a Gateway in a follow-up walkthrough.
// Going deeper
Related pages
Why Synefex
Open standards
Why we build on open standards, with the full list of standards we support.
Product
Gateway 2
The Gateway that runs your connectors, with Gateway timestamps and an audit trail.
Product
Connector Library
Our Connector Library covers 80+ instruments, all ready for OPC UA / LADS.