// Instrument vendor

Sartorius.

Sartorius makes lab balances, which sit at the start of many analytical workflows. Every Sartorius balance speaks SBI, the Sartorius Balance Interface, over USB, RS-232 or Ethernet. We connect your Sartorius balances to your LIMS, ELN or data lake. Each reading arrives with a Gateway timestamp, independent of the balance clock.

Cubis II, Practum and Quintix balances, connected to your systems over SBI.

Laboratory technician in a white coat and blue nitrile gloves using a spatula to add a white powder sample to a foil weighing boat inside the glass draft shield of an analytical balance on a granite weighing table

// About Sartorius

Balance data in your audit trail

A balance reading often feeds a formulation or assay result. Each reading carries a Gateway timestamp, and the Gateway’s audit trail records who did what, and when.

Cubis II: analytical and microbalances, used in formulation, QC and analytical labs.

Practum and Quintix: lab balances, used in academic and QC labs.

We read SBI and deliver your data over OPC UA / LADS, the OPC UA standard for laboratory devices.

// Manual records

Today

A weighing happens at 14:32 on a Cubis II. The balance has its own clock. The operator copies the value into a paper logbook or Excel. The method, calibration state and room conditions are recorded somewhere else. To verify one reading, your auditor checks three sources.

// Connected data

Connected

The same weighing now carries its value and units, and a Gateway timestamp independent of the balance clock. Ask us which method, calibration and operator data we can carry with it for your models.

// What you get

What you get with connected Sartorius balances

1

Connect your Sartorius balances

We capture from Cubis II, Practum, Quintix and the other Sartorius balances. Tell us your models and configuration, and we’ll confirm the connector status: Available, In testing or On request.

2

A Gateway timestamp on every reading

Every reading carries a Gateway timestamp, independent of the balance clock. The Gateway sets it, so it stays as recorded. Ask us about including calibration data in your records.

3

Structured data for your LIMS and ELN

Your Sartorius readings reach your LIMS, ELN or in-house systems over OPC UA / LADS by default, or as REST or AnIML where you need them. We set up the route and scope each LIMS or ELN integration with you.

4

An audit trail you can export

Export the Gateway’s audit trail as JSON or CSV, or as Syslog on request. Signed exports let the recipient verify the file. You set the retention.

One interface for every Sartorius balance

SBI
Sartorius Balance Interface, over USB, RS-232 or Ethernet
Cubis II · Practum · Quintix · other Sartorius balances
We confirm the connector status for your model.
We connect your Sartorius balances and deliver their data, timestamped and in context, to your LIMS, ELN or data lake.

Want your Sartorius balances connected to your LIMS or ELN?

Tell us your Sartorius models and configuration, and your target systems (LIMS, ELN, data lake). We come back with the connector mapping and a scoped proposal.

    Scientist in a lab coat explains something with open hand gestures to a listening colleague in a laboratory

    // Read next

    More on instruments and connectors

    Integrations

    All instrument vendors

    Browse the instrument vendor index, sorted by category. We confirm the status for your model.

    Products

    Connector Library

    Our Connector Library covers 80+ instruments. Send us your model, and we’ll confirm its status.

    Contact

    Talk to us about your lab

    A 30-minute first call about your instruments and systems. Then we come back with a plan for your setup.